Cement and Concrete Removal
Precision Water Jet Cutting
Precision Water Jet Cutting applies a High Pressure/ Low Volume Water Jet from a special designed transporter, featuring a Pan & Tilt nozzle and CCTV camera module, to remove deposits settled and solid obstructions from within 6" - 36" (150-900mm) pipes and service lateral connections.
Up to 32,000psi Precision water jet cutting removes: grease films, debris, tree roots, hardened fat, solidified grease, cement, scale, tuberculation, corrosion, years off mineral deposits and calcium build- up, grout and over- poured concrete for the elimination of obstructions and to prepare pipes for rehabilitation.
With eyes on the job, continuous adjustment of pressure, angle of attack and distance to material enable the operator to achieve the breakdown and elimination of various obstructions without adding damage to the pipe structure.
Precision water jet cutting
- Powerful
- Controlled
- Eyes on the job
Precision Water Jet Cutting Modules
The available modules for precision water jet cutting are: WJ125 for 6" - 15" (150-375mm), WJ160 for 8" - 15" (200-375mm), WJ180 for 8" - 20" (200-500mm) and WJ190 for 10" - 36" (250-900mm). Click products for technical specifications.
Operator Removes Grout from 8" Sewer Pipe
Obstruction(s): Settled grout deposits
Pipe Diameter: 8" (200mm)
Pipe Material: Concrete
Water Pressure: <14,500psi (<1000bar)
Used ID-tec Equipment: R125 transporter, WJ125 Precision Water Jet Cutting Module, CP3D Control Unit, MH Cable and Hose reels, HDE37 - 14,500psi High Pressure Unit, Vehicle Installed.
25 Cubix Yards Concrete Aggregate Removed from 18" Sewer Main
Obstruction(s): about 25 cubic yards of aggregate concrete that was accidentally dumped into an 18" sewer main during soil stabilization at a development project.
Pipe Diameter: 18" (450mm)
Pipe Material: VCP (lined)
Water Pressure: 14,500psi (1000bar)
Used ID-tec Equipment: R160 transporter, WJ180 Precision Water Jet Cutting Module, CP3D Control Unit, MH Cable and Hose reels, HDM37 - 14,500psi High Pressure Unit, Vehicle Installed.
Concrete Removal from 8" Main line at Lateral Connection
Obstruction(s): Concrete entered 8" main line from service lateral connection and settled.
Pipe Diameter: 8" (200mm)
Pipe Material: VCP
Water Pressure: 7,250psi (500bar)
Used ID-tec Equipment: R125 transporter, WJ125 Precision Water Jet Cutting Module with Rotary Nozzle, CP3D Control Unit, MH Cable and Hose reels, HDM19 - 7,250psi High Pressure Unit, Vehicle Installed
Cement Removal
Obstruction(s): Cement settled above the flow from 9 to 3 o'clock
Pipe Diameter: 12" (300mm)
Pipe Material: Concrete
Water Pressure: 11,000psi (750bar)
Used ID-tec Equipment: R160 transporter, WJ180 Precision Water Jet Cutting Module, CP3D Control Unit, MH Cable and Hose reels, HDM37 - 14,500psi High Pressure Unit, Vehicle Installed